Availability: | |
---|---|
Latching Relay | |
Part Number | |
Coil Voltage | |
D= Double Coil; S= Single Coil | |
80=80A |
Characteristics
Insulation resistance | 1000MΩ (500VDC) | |
Dielectric Strength | Between Coil& Contacts | 4000VAC 1min |
Between Open Contacts | 2000VAC 1 min | |
Operate Time | 20msec. Max. | |
Release Time | 20msec. Max. | |
Shock resistance | Functional | 98m/S 2 (10g) |
Destructive | 980m/S 2 (100g) | |
Vibration resistance | 10~55Hz 1.5mm | |
Humidity | 95%RH ,40℃ | |
Ambient temperature | -40~+70℃ | |
Temination | Fast connection | |
Unit weight | 50g | |
Constrution | Dust protected |
Contact Data
Contact form | 1A/1B |
Contact material | AgSnO2 |
Contact resistance | Max: 1.2mΩ |
Contact Rating | 80A 250VAC |
Max. Switching Power | 20000VA |
Mechanical life | 5×105 |
Electrical life | 1×104 |
Coil
Coil power | Single coil: 1.5W Double coil: 3.0W |
Coil Data
Rated Voltage(VDC) | Pick-up voltage(VDC) | Pulse Duration(ms) | Coil Resistance (Ω) |
Single coil | |||
9 | 6.8 | 50 | 50±10% |
12 | 9 | 50 | 96±10% |
24 | 18 | 50 | 384±10% |
48 | 36 | 50 | 1536±10% |
Double coil | |||
9 | 6.8 | 50 | 2×25±10% |
12 | 9 | 50 | 2×48±10% |
24 | 18 | 50 | 2×192±10% |
48 | 36 | 50 | 2×768±10% |
Typical Application
1) Prepayment Energy Meter; AMR System;
2) Compound Switch; Automatic Control System
Latching Relay | |
Part Number | |
Coil Voltage | |
D= Double Coil; S= Single Coil | |
80=80A |
Characteristics
Insulation resistance | 1000MΩ (500VDC) | |
Dielectric Strength | Between Coil& Contacts | 4000VAC 1min |
Between Open Contacts | 2000VAC 1 min | |
Operate Time | 20msec. Max. | |
Release Time | 20msec. Max. | |
Shock resistance | Functional | 98m/S 2 (10g) |
Destructive | 980m/S 2 (100g) | |
Vibration resistance | 10~55Hz 1.5mm | |
Humidity | 95%RH ,40℃ | |
Ambient temperature | -40~+70℃ | |
Temination | Fast connection | |
Unit weight | 50g | |
Constrution | Dust protected |
Contact Data
Contact form | 1A/1B |
Contact material | AgSnO2 |
Contact resistance | Max: 1.2mΩ |
Contact Rating | 80A 250VAC |
Max. Switching Power | 20000VA |
Mechanical life | 5×105 |
Electrical life | 1×104 |
Coil
Coil power | Single coil: 1.5W Double coil: 3.0W |
Coil Data
Rated Voltage(VDC) | Pick-up voltage(VDC) | Pulse Duration(ms) | Coil Resistance (Ω) |
Single coil | |||
9 | 6.8 | 50 | 50±10% |
12 | 9 | 50 | 96±10% |
24 | 18 | 50 | 384±10% |
48 | 36 | 50 | 1536±10% |
Double coil | |||
9 | 6.8 | 50 | 2×25±10% |
12 | 9 | 50 | 2×48±10% |
24 | 18 | 50 | 2×192±10% |
48 | 36 | 50 | 2×768±10% |
Typical Application
1) Prepayment Energy Meter; AMR System;
2) Compound Switch; Automatic Control System