Availability: | |
---|---|
◆ Characteristic
> Small size, 100A switching capability.
> Low coil consumption, ultra-low temperature rise.
> Low contact resistance.
> Strong anti-shock and anti-vibration capability.
> Outline size: 40.4×30.0×17.0mm.
Ordering Information
Latching Relay | |
Part Number | |
Coil Voltage | |
D= Double Coil; S= Single Coil | |
100=100A |
Characteristics
Insulation resistance | 1000MΩ (500VDC) | |
Dielectric Strength | Between Coil& Contacts | 4000VAC 1min |
Between Open Contacts | 2000VAC 1 min | |
Operate Time | 20msec. Max. | |
Release Time | 20msec. Max. | |
Shock resistance | Functional | 98m/S2 (10g) |
Destructive | 980m/S 2 (100g) | |
Vibration resistance | 10~55Hz 1.5mm | |
Humidity | 95%RH ,40℃ | |
Ambient temperature | -40~+80℃ | |
Temination | Fast connection | |
Unit weight | 65g | |
Constrution | Dust protected |
Contact Data
Contact form | 1A/1B |
Contact material | AgSnO2 |
Contact resistance | Max: 1.0mΩ |
Contact Rating | 100A 250VAC |
Max. Switching Power | 25000VA |
Mechanical life | 5×105 |
Electrical life | 1×104 |
Coil
Coil power | Single coil: 2.3W Double coil: 4.6W |
Coil Data
Rated Voltage(VDC) | Pick-up voltage(VDC) | Pulse Duration(ms) | Coil Resistance (Ω) |
Single coil | |||
9 | 6.8 | 50 | 35±10% |
12 | 9 | 50 | 63±10% |
24 | 18 | 50 | 250±10% |
48 | 36 | 50 | 1000±10% |
Double coil | |||
9 | 6.8 | 50 | 2×17.5±10% |
12 | 9 | 50 | 2×31±10% |
24 | 18 | 50 | 2×125±10% |
48 | 36 | 50 | 2×500±10% |
Note: Special ordering for other coil voltage.
Typical Application
1) Prepayment Energy Meter; AMR System;
2) Compound Switch; Automatic Control System
Dimensions(mm)/Circuit Diagram
◆ Characteristic
> Small size, 100A switching capability.
> Low coil consumption, ultra-low temperature rise.
> Low contact resistance.
> Strong anti-shock and anti-vibration capability.
> Outline size: 40.4×30.0×17.0mm.
Ordering Information
Latching Relay | |
Part Number | |
Coil Voltage | |
D= Double Coil; S= Single Coil | |
100=100A |
Characteristics
Insulation resistance | 1000MΩ (500VDC) | |
Dielectric Strength | Between Coil& Contacts | 4000VAC 1min |
Between Open Contacts | 2000VAC 1 min | |
Operate Time | 20msec. Max. | |
Release Time | 20msec. Max. | |
Shock resistance | Functional | 98m/S2 (10g) |
Destructive | 980m/S 2 (100g) | |
Vibration resistance | 10~55Hz 1.5mm | |
Humidity | 95%RH ,40℃ | |
Ambient temperature | -40~+80℃ | |
Temination | Fast connection | |
Unit weight | 65g | |
Constrution | Dust protected |
Contact Data
Contact form | 1A/1B |
Contact material | AgSnO2 |
Contact resistance | Max: 1.0mΩ |
Contact Rating | 100A 250VAC |
Max. Switching Power | 25000VA |
Mechanical life | 5×105 |
Electrical life | 1×104 |
Coil
Coil power | Single coil: 2.3W Double coil: 4.6W |
Coil Data
Rated Voltage(VDC) | Pick-up voltage(VDC) | Pulse Duration(ms) | Coil Resistance (Ω) |
Single coil | |||
9 | 6.8 | 50 | 35±10% |
12 | 9 | 50 | 63±10% |
24 | 18 | 50 | 250±10% |
48 | 36 | 50 | 1000±10% |
Double coil | |||
9 | 6.8 | 50 | 2×17.5±10% |
12 | 9 | 50 | 2×31±10% |
24 | 18 | 50 | 2×125±10% |
48 | 36 | 50 | 2×500±10% |
Note: Special ordering for other coil voltage.
Typical Application
1) Prepayment Energy Meter; AMR System;
2) Compound Switch; Automatic Control System
Dimensions(mm)/Circuit Diagram